8S 200A BMS of LiFePO4 Battery Replacement for Lead-Acid Battery - AYAA

BMS of LiFePO4 Battery Replacement for Lead-Acid Battery Model: PCM-L08S200-L13 Test item(Test at normal temperature 25±2℃ ) Criterion Voltage Charging voltage DC:27.6V~28.8V CC/CV(3.45V~4.2V/Cell)8s ... - AYAA

INQUIRY NOW LINKEDIN FACEBOOK YOUTUBE
  • 8S 200A BMS of LiFePO4 Battery Replacement for Lead-Acid Battery
  • 8S 200A BMS of LiFePO4 Battery Replacement for Lead-Acid Battery
  • 8S 200A BMS of LiFePO4 Battery Replacement for Lead-Acid Battery
  • 8S 200A BMS of LiFePO4 Battery Replacement for Lead-Acid Battery
  • 8S 200A BMS of LiFePO4 Battery Replacement for Lead-Acid Battery
  • 8S 200A BMS of LiFePO4 Battery Replacement for Lead-Acid Battery
  • 8S 200A BMS of LiFePO4 Battery Replacement for Lead-Acid Battery
  • 8S 200A BMS of LiFePO4 Battery Replacement for Lead-Acid Battery
  • 8S 200A BMS of LiFePO4 Battery Replacement for Lead-Acid Battery
  • 8S 200A BMS of LiFePO4 Battery Replacement for Lead-Acid Battery

8S 200A BMS of LiFePO4 Battery Replacement for Lead-Acid Battery

  • Model:PCM-L08S200-L13 
  • Working Current:200A
  • Size:L200*W110*T14.5mm
  • Battery Type:Li-ion/LiFePO4
  • Battery Series:8S
Inquire Online Download
Parameter information Product Detail

BMS of LiFePO4 Battery Replacement for Lead-Acid Battery

Model: PCM-L08S200-L13
Test item(Test at normal temperature 25±2℃ )Criterion
VoltageCharging voltageDC:27.6V~28.8V CC/CV(3.45V~4.2V/Cell)8s
Supply CurrentNormal operating mode current:Fuel gauge in NORMAL mode. ILOAD >Sleep Current≤50uA
Maximal continuous charging current30-200A
Maximal continuous discharging current30-200A
Balance current for single cell36-42mA
Over-charge Protection
(single cell)
Balance voltage for single cell3.6-4.20V
Over charge detection voltage3.6-4.40V
Over charge detection delay time0.5S—2S
Over charge release voltage3.5-4.30V
Over discharge protection
(single cell)
Over discharge detection voltage2.4-3.0V
Over discharge detection delay time10—200mS
Over discharge release voltage2.6-3.4V
Current protection
(Battery pack)
Discharge Over current detection current90-600A
Detection delay time 5ms—20ms
Release conditionCut load,Auto Recovery
Short protectionDetection conditionExterior short circuit
Detection delay time200-600us
Release conditionCut load
ResistanceMain loop electrify resistance ≤65mΩ
TemperatureOperating Temperature Range-40~+85℃
Storage Temperature Range-40~+125℃
Pre-charge/discharge,Anti-Reverse Connection
SIZE: L200 *W115 *T14.5 mm
NTC: 10K NTC Temperature switch:90℃ Weak current switch:YES Activation Method:/
Chat With Us

Leave Your Message

  • Message