Marine & Boat BMS
Power your marine adventures with Ayaa Solar Generators.
View More >BMS of LiFePO4 Battery Replacement for Lead-Acid Battery Model:PCM-L15S50-L46 No. Test item (Test at normal temperature 25±2℃ and relative humidity≤90%) Criterion 1 Communication Interface RS485&U ... - AYAA
Model:PCM-L15S50-L46 | ||||
No. | Test item (Test at normal temperature 25±2℃ and relative humidity≤90%) | Criterion | ||
1 | Communication Interface | RS485&UART &Bluetooth | ||
2 | Voltage | Charging voltage | DC:51.75V~63V CC/CV(3.45V~4.2V/Cell)15s | |
Cell-balance detection voltage(Charge balance) | can be adjusted by required | |||
Cell-balance detection delay time | 0.5S—2S | |||
3 | Current | Balance current for single cell | 32-58mA | |
Normal operating-mode current (Gas Gauge IC) | 600 uA(average) | |||
SLEEP operating-mode current (Gas Gauge IC) | 350 uA(average) | |||
Maximal continuous charging current | 20-50A | |||
Maximal continuous discharging current | 20-50A | |||
4 | Over charge Protection (single cell) | Over charge detection voltage | 3.6-4.35V | |
Over charge detection delay time | 0.5S—2S | |||
Over charge release voltage | 3.4-4.15V | |||
5 | Over discharge protection (single cell) | Over discharge detection voltage | 2.0-3.0V | |
Over discharge detection delay time | 150—300mS | |||
Over discharge release voltage | 2.3-3.2V | |||
6 | Over current protection(Battery pack) | Over current detection current | 60-150A | |
Detection delay time | 50ms—300ms | |||
Release condition | Cut load,Auto Recovery | |||
7 | Short protection | Detection condition | Exterior short circuit | |
Detection delay time | 200-800us | |||
Release condition | Cut load,Auto Recovery | |||
8 | Resistance | Protection circuitry (MOSFET) | ≤50mΩ | |
9 | Temperature | Operating Temperature Range | -40~+85℃ | |
Storage Temperature Range | -40~+125℃ | |||
SIZE: L155 *W63*T15mm | ||||
NTC: 10K NTC Temperature switch:/ Weak current switch:/ Activation Method:/ |