BMS/PCM with Communications Battery Management System Specifications Model: AY-L12S80A-M067 No. Test Item (Test at normal temperature 25±2°C and relative humidity ≤90%) Criterion 1 Communication Interface RS485 & CANBUS 2 Voltage DC: 41.4V–50.4V (3.45V–4.2V/Cell) 12s Balance Mode Active battery balance Balance on Condition Reach the user-defined activation voltage and differential voltage. Detection voltage of single string 2-5V, and equalizing activation differential voltage (Adjacent strings): ≥220mV (factory default) 3 Supply Current Normal operating-mode current (Gas Gauge IC) ≤10mA (average) SLEEP operating-mode current (Gas Gauge IC) ≤150µA (average) Maximal continuous charging current 20A–80A Maximal continuous discharging current 20A–80A 4 Overcharge Protection (single cell) Overcharge detection voltage 3.6–4.35V Overcharge detection delay time 0.5s–2s Overcharge release voltage 3.4–4.15V 5 Over Discharge Protection (single cell) Over discharge detection voltage 2.0–3.0V Over discharge detection delay time 150ms–300ms Over discharge release voltage 2.3–3.2V 6 Overcurrent Protection (Battery pack) Overcharge current protection 30A–90A Detection delay time 1s Overcurrent detection current 1 60A–240A Detection delay time 2–5s Overcurrent detection current 2 120A–480A Detection delay time 50ms–300ms Release condition Cut load, Auto Recovery 7 Short Protection Detection condition Exterior short circuit Detection delay time 200ms–800ms Release condition Cut load, Auto Recovery 8 Resistance Protection circuitry (MOSFET) ≤50mΩ 9 Temperature Operating Temperature ... - AYAA TECHNOLOGY CO., LTD
BMS/PCM with Communications
BMS/PCM with Communications Battery Management System Specifications Model: AY-L12S80A-M067 No. Test Item (Test at normal temperature 25±2°C and relative humidity ≤90%) Criterion 1 Communication Interface RS485 & CANBUS 2 Voltage DC: 41.4V–50.4V (3.45V–4.2V/Cell) 12s Balance Mode Active battery balance Balance on Condition Reach the user-defined activation voltage and differential voltage. Detection voltage of single string 2-5V, and equalizing activation differential voltage (Adjacent strings): ≥220mV (factory default) 3 Supply Current Normal operating-mode current (Gas Gauge IC) ≤10mA (average) SLEEP operating-mode current (Gas Gauge IC) ≤150µA (average) Maximal continuous charging current 20A–80A Maximal continuous discharging current 20A–80A 4 Overcharge Protection (single cell) Overcharge detection voltage 3.6–4.35V Overcharge detection delay time 0.5s–2s Overcharge release voltage 3.4–4.15V 5 Over Discharge Protection (single cell) Over discharge detection voltage 2.0–3.0V Over discharge detection delay time 150ms–300ms Over discharge release voltage 2.3–3.2V 6 Overcurrent Protection (Battery pack) Overcharge current protection 30A–90A Detection delay time 1s Overcurrent detection current 1 60A–240A Detection delay time 2–5s Overcurrent detection current 2 120A–480A Detection delay time 50ms–300ms Release condition Cut load, Auto Recovery 7 Short Protection Detection condition Exterior short circuit Detection delay time 200ms–800ms Release condition Cut load, Auto Recovery 8 Resistance Protection circuitry (MOSFET) ≤50mΩ 9 Temperature Operating Temperature ... - AYAA TECHNOLOGY CO., LTD
No. | Test Item (Test at normal temperature 25±2°C and relative humidity ≤90%) | Criterion |
---|---|---|
1 | Communication Interface | RS485 & CANBUS |
2 | Voltage | DC: 41.4V–50.4V (3.45V–4.2V/Cell) 12s |
Balance Mode | Active battery balance | |
Balance on Condition | Reach the user-defined activation voltage and differential voltage. Detection voltage of single string 2-5V, and equalizing activation differential voltage (Adjacent strings): ≥220mV (factory default) | |
3 | Supply Current | |
Normal operating-mode current (Gas Gauge IC) | ≤10mA (average) | |
SLEEP operating-mode current (Gas Gauge IC) | ≤150µA (average) | |
Maximal continuous charging current | 20A–80A | |
Maximal continuous discharging current | 20A–80A | |
4 | Overcharge Protection (single cell) | |
Overcharge detection voltage | 3.6–4.35V | |
Overcharge detection delay time | 0.5s–2s | |
Overcharge release voltage | 3.4–4.15V | |
5 | Over Discharge Protection (single cell) | |
Over discharge detection voltage | 2.0–3.0V | |
Over discharge detection delay time | 150ms–300ms | |
Over discharge release voltage | 2.3–3.2V | |
6 | Overcurrent Protection (Battery pack) | |
Overcharge current protection | 30A–90A | |
Detection delay time | 1s | |
Overcurrent detection current 1 | 60A–240A | |
Detection delay time | 2–5s | |
Overcurrent detection current 2 | 120A–480A | |
Detection delay time | 50ms–300ms | |
Release condition | Cut load, Auto Recovery | |
7 | Short Protection | |
Detection condition | Exterior short circuit | |
Detection delay time | 200ms–800ms | |
Release condition | Cut load, Auto Recovery | |
8 | Resistance | Protection circuitry (MOSFET) ≤50mΩ |
9 | Temperature | |
Operating Temperature Range | -40°C ~ +85°C | |
Storage Temperature Range | -40°C ~ +125°C | |
Size | L: 188mm * W: 110mm * T: 20mm | |
NTC: 10K NTC*3pcs | Temperature switch: / Weak current switch: YES, Activation Method: / |