BMS/PCM with Communications - AYAA TECHNOLOGY CO., LTD

BMS/PCM with Communications Model: AY-LB10S5A-T013 Ver: A Test item(Test at normal temperature 25±2℃ ) Criterion Communication Interface SMBUS Voltage Charging voltage DC:42V CC/CV(4.2v/Cell)10s Capacity Designing battery capacity(PCM) /Ah Supply Current Normal operating mode current: Fuel gauge in NORMAL mode. ILOAD >Sleep Current ≤860uA Low-power operating mode current: Fuel gauge in SLEEP mode.ILOAD < Sleep Current ≤430 uA Low-power operating mode current: Fuel gauge in FULLSLEEP mode.ILOAD < Sleep Current ≤12uA Maximal continuous charging current 5A Maximal continuous discharging current 5A Balance current for single cell 42±10mA Over-charge Protection(single cell) Balance voltage for single cell 4.0V±0.05V Over charge detection voltage 4.30±0.05V Over charge detection delay time 0.5S—2S Over charge release voltage 4.10±0.1V Over discharge protection(single cell) Over discharge detection voltage 2.8±0.05V Over discharge detection delay time 0.5S—2S Over discharge release voltage 3.0±0.1V Current protection(Battery pack) ChargeOver current detection current 10±3A Detection delay time 0.5S—2S Discharge Over current detection current 20±5A Detection delay time 0.5S—2S Release condition Cut load, Auto Recovery Short protection Detection condition Exterior short circuit Detection delay time 200-600us Release condition Cut load Resistance Main loop electrify resistance ≤ 30mΩ Temperature discharge temperature protection -10~+65℃ charge temperature protection 0~+60℃ Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ SIZE: L65*W35*T5 ... - AYAA TECHNOLOGY CO., LTD

INQUIRY NOW LINKEDIN FACEBOOK YOUTUBE
  • BMS/PCM with Communications
  • BMS/PCM with Communications
  • BMS/PCM with Communications
  • BMS/PCM with Communications
  • BMS/PCM with Communications
  • BMS/PCM with Communications
  • BMS/PCM with Communications
  • BMS/PCM with Communications
  • BMS/PCM with Communications
  • BMS/PCM with Communications

BMS/PCM with Communications

  • Model:AY-LB10S5A-T013
  • Working Current:5A
  • Size:L65*W35*T5 mm
  • Battery Type:Li-ion/Li-Po/LiFePO4
  • Battery Series:10S
Inquire Online Download
Parameter information Product Detail

BMS/PCM with Communications

Model: AY-LB10S5A-T013 Ver: A
Test item(Test at normal temperature 25±2℃ )Criterion
Communication InterfaceSMBUS
VoltageCharging voltageDC:42V CC/CV(4.2v/Cell)10s
CapacityDesigning battery capacity(PCM)/Ah
Supply CurrentNormal operating mode current: Fuel gauge in NORMAL mode. ILOAD >Sleep Current≤860uA
Low-power operating mode current: Fuel gauge in SLEEP mode.ILOAD < Sleep Current≤430 uA
Low-power operating mode current: Fuel gauge in FULLSLEEP mode.ILOAD < Sleep Current≤12uA
Maximal continuous charging current5A
Maximal continuous discharging current5A
Balance current for single cell42±10mA
Over-charge Protection
(single cell)
Balance voltage for single cell4.0V±0.05V
Over charge detection voltage4.30±0.05V
Over charge detection delay time0.5S—2S
Over charge release voltage4.10±0.1V
Over discharge protection
(single cell)
Over discharge detection voltage2.8±0.05V
Over discharge detection delay time0.5S—2S
Over discharge release voltage3.0±0.1V
Current protection
(Battery pack)
ChargeOver current detection current10±3A
Detection delay time0.5S—2S
Discharge Over current detection current20±5A
Detection delay time0.5S—2S
Release conditionCut load, Auto Recovery
Short protectionDetection conditionExterior short circuit
Detection delay time200-600us
Release conditionCut load
ResistanceMain loop electrify resistance≤ 30mΩ
Temperaturedischarge temperature protection-10~+65℃
charge temperature protection0~+60℃
Operating Temperature Range-40~+85℃
Storage Temperature Range-40~+125℃
SIZE: L65*W35*T5 mm
NTC: 10KNTC B=3435 Temperature switch: / ℃ (the batteries temperature) Weak current switch:/ Activation Method:/
Chat With Us

Leave Your Message

  • Message