BMS/PCM with Communications Model: AY-LB10S5A-T013 Ver: A Test item(Test at normal temperature 25±2℃ ) Criterion Communication Interface SMBUS Voltage Charging voltage DC:42V CC/CV(4.2v/Cell)10s Capacity Designing battery capacity(PCM) /Ah Supply Current Normal operating mode current: Fuel gauge in NORMAL mode. ILOAD >Sleep Current ≤860uA Low-power operating mode current: Fuel gauge in SLEEP mode.ILOAD < Sleep Current ≤430 uA Low-power operating mode current: Fuel gauge in FULLSLEEP mode.ILOAD < Sleep Current ≤12uA Maximal continuous charging current 5A Maximal continuous discharging current 5A Balance current for single cell 42±10mA Over-charge Protection(single cell) Balance voltage for single cell 4.0V±0.05V Over charge detection voltage 4.30±0.05V Over charge detection delay time 0.5S—2S Over charge release voltage 4.10±0.1V Over discharge protection(single cell) Over discharge detection voltage 2.8±0.05V Over discharge detection delay time 0.5S—2S Over discharge release voltage 3.0±0.1V Current protection(Battery pack) ChargeOver current detection current 10±3A Detection delay time 0.5S—2S Discharge Over current detection current 20±5A Detection delay time 0.5S—2S Release condition Cut load, Auto Recovery Short protection Detection condition Exterior short circuit Detection delay time 200-600us Release condition Cut load Resistance Main loop electrify resistance ≤ 30mΩ Temperature discharge temperature protection -10~+65℃ charge temperature protection 0~+60℃ Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ SIZE: L65*W35*T5 ... - AYAA TECHNOLOGY CO., LTD
Model: AY-LB10S5A-T013 Ver: A | ||
Test item(Test at normal temperature 25±2℃ ) | Criterion | |
Communication Interface | SMBUS | |
Voltage | Charging voltage | DC:42V CC/CV(4.2v/Cell)10s |
Capacity | Designing battery capacity(PCM) | /Ah |
Supply Current | Normal operating mode current: Fuel gauge in NORMAL mode. ILOAD >Sleep Current | ≤860uA |
Low-power operating mode current: Fuel gauge in SLEEP mode.ILOAD < Sleep Current | ≤430 uA | |
Low-power operating mode current: Fuel gauge in FULLSLEEP mode.ILOAD < Sleep Current | ≤12uA | |
Maximal continuous charging current | 5A | |
Maximal continuous discharging current | 5A | |
Balance current for single cell | 42±10mA | |
Over-charge Protection (single cell) | Balance voltage for single cell | 4.0V±0.05V |
Over charge detection voltage | 4.30±0.05V | |
Over charge detection delay time | 0.5S—2S | |
Over charge release voltage | 4.10±0.1V | |
Over discharge protection (single cell) | Over discharge detection voltage | 2.8±0.05V |
Over discharge detection delay time | 0.5S—2S | |
Over discharge release voltage | 3.0±0.1V | |
Current protection (Battery pack) | ChargeOver current detection current | 10±3A |
Detection delay time | 0.5S—2S | |
Discharge Over current detection current | 20±5A | |
Detection delay time | 0.5S—2S | |
Release condition | Cut load, Auto Recovery | |
Short protection | Detection condition | Exterior short circuit |
Detection delay time | 200-600us | |
Release condition | Cut load | |
Resistance | Main loop electrify resistance | ≤ 30mΩ |
Temperature | discharge temperature protection | -10~+65℃ |
charge temperature protection | 0~+60℃ | |
Operating Temperature Range | -40~+85℃ | |
Storage Temperature Range | -40~+125℃ | |
SIZE: L65*W35*T5 mm | ||
NTC: 10KNTC B=3435 Temperature switch: / ℃ (the batteries temperature) Weak current switch:/ Activation Method:/ |