BMS/PCM with Communications Model: PCM-L12S10-C13(LI-12S10A) ver: A Test item(Test at normal temperature 25±2℃ ) Criterion Communication Interface I2C,Bluetooth Voltage Charging voltage DC:50.4V CC/CV(4.2v/Cell)12S Capacity Designing battery capacity(PCM) 320Ah Supply Current Normal operating mode current:Fuel gauge in NORMAL mode. ILOAD >Sleep Current ≤400uA Maximal continuous charging current 10A Maximal continuous discharging current 10A Balance current for single cell / Over-charge Protection (single cell) Balance voltage for single cell / Over charge detection voltage Optional Over charge detection delay time 0.5—2S Over charge release voltage Optional Over discharge protection(single cell) Over discharge detection voltage Optional Over discharge detection delay time 0.5—2S Over discharge release voltage Optional Current protection(Battery pack) Discharge Over current detection current Adjustable Detection delay time 100—800mS Release condition Cut load,Auto Recovery Short protection Detection condition Exterior short circuit Detection delay time 200-600us Release condition Cut load Resistance Main loop electrify resistance ≤50mΩ Temperature Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ SIZE:L80*W65*T10mm NTC:10KNTC B=3435 Temperature switch:70℃ Weak current switch:/ Activation Method:/ - AYAA TECHNOLOGY CO., LTD
Model: PCM-L12S10-C13(LI-12S10A) ver: A | ||
Test item(Test at normal temperature 25±2℃ ) | Criterion | |
Communication Interface | I2C,Bluetooth | |
Voltage | Charging voltage | DC:50.4V CC/CV(4.2v/Cell)12S |
Capacity | Designing battery capacity(PCM) | 320Ah |
Supply Current | Normal operating mode current:Fuel gauge in NORMAL mode. ILOAD >Sleep Current | ≤400uA |
Maximal continuous charging current | 10A | |
Maximal continuous discharging current | 10A | |
Balance current for single cell | / | |
Over-charge Protection (single cell) | Balance voltage for single cell | / |
Over charge detection voltage | Optional | |
Over charge detection delay time | 0.5—2S | |
Over charge release voltage | Optional | |
Over discharge protection (single cell) | Over discharge detection voltage | Optional |
Over discharge detection delay time | 0.5—2S | |
Over discharge release voltage | Optional | |
Current protection (Battery pack) | Discharge Over current detection current | Adjustable |
Detection delay time | 100—800mS | |
Release condition | Cut load,Auto Recovery | |
Short protection | Detection condition | Exterior short circuit |
Detection delay time | 200-600us | |
Release condition | Cut load | |
Resistance | Main loop electrify resistance | ≤50mΩ |
Temperature | Operating Temperature Range | -40~+85℃ |
Storage Temperature Range | -40~+125℃ | |
SIZE:L80*W65*T10mm | ||
NTC:10KNTC B=3435 Temperature switch:70℃ Weak current switch:/ Activation Method:/ |