PCM for 10S-16S PCM-L16S15-582(16S) No Test item Criterion Lifepo4 Li-ion/Li-polymer 1 Voltage Charging voltage DC 57.6V CC/CV(3.6V/cell) DC:67.2V CC/CV(4.2V/cell) Balance voltage for single cell 3.60±0.025V 4.20±0.025V 2 Current Balance current for single cell 72±10mA 84±10mA Current consumption for single cell ≤20μA ≤20μA Max. continuous charging current 15A 15A Max. cont. discharging current 15A 15A 3 Over charge protection(single cell) Over charge detection voltage 3.65V±0.025V(optional) 4.25±0.025V(optional) Over charge detection delay time 0.5-2.0S 0.5S—2.0S Over charge release voltage 3.65±0.05V 4.15 ±0.05V 4 Over discharge protection(single cell) Over discharge detection voltage 2.00±0.8V(optional) 2.5±0.08V(optional) Over discharge detection delay time 10-300mS 10-300mS Over discharge release voltage 2.3±0.1V 3.0±0.1V 5 Over current protection Over current detection voltage depend on the above points depend on the above points Over current detection current final data fixed from actual test final data fixed from actual test Detection delay time 5-20ms 5-20ms Release condition Cut load,Auto release Cut load,Auto release 6 Short protection Detection condition Exterior short circuit Detection delay time 100~500us Release condition charge up 7 Resistance Protection circuitry ≤50mΩ 8 Temperature Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ 9 Dimension L128*50*T12mm Optional Parameters: Over charge detection voltage (V) 3.65±0.025V 4.25±0.025V 4.28±0.025V Over charge release ... - AYAA TECHNOLOGY CO., LTD
No | Test item | Criterion | |||
Lifepo4 | Li-ion/Li-polymer | ||||
1 | Voltage | Charging voltage | DC 57.6V CC/CV(3.6V/cell) | DC:67.2V CC/CV(4.2V/cell) | |
Balance voltage for single cell | 3.60±0.025V | 4.20±0.025V | |||
2 | Current | Balance current for single cell | 72±10mA | 84±10mA | |
Current consumption for single cell | ≤20μA | ≤20μA | |||
Max. continuous charging current | 15A | 15A | |||
Max. cont. discharging current | 15A | 15A | |||
3 | Over charge protection(single cell) | Over charge detection voltage | 3.65V±0.025V(optional) | 4.25±0.025V(optional) | |
Over charge detection delay time | 0.5-2.0S | 0.5S—2.0S | |||
Over charge release voltage | 3.65±0.05V | 4.15 ±0.05V | |||
4 | Over discharge protection(single cell) | Over discharge detection voltage | 2.00±0.8V(optional) | 2.5±0.08V(optional) | |
Over discharge detection delay time | 10-300mS | 10-300mS | |||
Over discharge release voltage | 2.3±0.1V | 3.0±0.1V | |||
5 | Over current protection | Over current detection voltage | depend on the above points | depend on the above points | |
Over current detection current | final data fixed from actual test | final data fixed from actual test | |||
Detection delay time | 5-20ms | 5-20ms | |||
Release condition | Cut load,Auto release | Cut load,Auto release | |||
6 | Short protection | Detection condition | Exterior short circuit | ||
Detection delay time | 100~500us | ||||
Release condition | charge up | ||||
7 | Resistance | Protection circuitry | ≤50mΩ | ||
8 | Temperature | Operating Temperature Range | -40~+85℃ | ||
Storage Temperature Range | -40~+125℃ | ||||
9 | Dimension | L128*50*T12mm | |||
Optional Parameters: | Over charge detection voltage (V) | 3.65±0.025V | 4.25±0.025V | 4.28±0.025V | |
Over charge release voltage(V) | 3.65±0.05V | 4.05±0.05V | 4.08±0.05V | ||
Over discharge detection voltage | 2.50±0.8V | 2.80±0.8V | 3.00±0.8V | ||
Over discharge release voltage(V) | 3.00±0.1V | 3.00±0.1V | 3.00±0.1V |