PCM for 17S-35S Model: PCM-L17S70-F95(LI-ION-17S70A) ver: A Test item(Test at normal temperature 25±2℃ ) Criterion Voltage Charging voltage DC:71.2V CC/CV(4.2V/Cell)17S Supply Current Normal operating mode current:Fuel gauge in NORMAL mode. ILOAD >Sleep Current ≤50uA Maximal continuous charging current 40A Maximal continuous discharging current 40A Balance current for single cell 42±10mA Over-charge Protection (single cell) Balance voltage for single cell 4.20V±0.05V Over charge detection voltage 4.25±0.05V Over charge detection delay time 0.5S—2S Over charge release voltage 4.15±0.1V Over discharge protection(single cell) Over discharge detection voltage 2.75±0.05V Over discharge detection delay time 1—3S Over discharge release voltage 3.0±0.1V Current protection(Battery pack) ChargeOver current detection current / Detection delay time / Discharge Over current detection current 150±30A Detection delay time 50-350mS Release condition Cut load,Auto Recovery Short protection Detection condition Exterior short circuit Detection delay time 200-600us Release condition Cut load Resistance Main loop electrify resistance ≤20mΩ Temperature high temperature discharge protection 60℃ Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ SIZE: L120*W80*T21mm NTC: / Temperature switch: 60℃ (the batteries temperature) Weak current switch:/ Activation Method:/ - AYAA TECHNOLOGY CO., LTD
Model: PCM-L17S70-F95(LI-ION-17S70A) ver: A | ||
Test item(Test at normal temperature 25±2℃ ) | Criterion | |
Voltage | Charging voltage | DC:71.2V CC/CV(4.2V/Cell)17S |
Supply Current | Normal operating mode current:Fuel gauge in NORMAL mode. ILOAD >Sleep Current | ≤50uA |
Maximal continuous charging current | 40A | |
Maximal continuous discharging current | 40A | |
Balance current for single cell | 42±10mA | |
Over-charge Protection (single cell) | Balance voltage for single cell | 4.20V±0.05V |
Over charge detection voltage | 4.25±0.05V | |
Over charge detection delay time | 0.5S—2S | |
Over charge release voltage | 4.15±0.1V | |
Over discharge protection (single cell) | Over discharge detection voltage | 2.75±0.05V |
Over discharge detection delay time | 1—3S | |
Over discharge release voltage | 3.0±0.1V | |
Current protection (Battery pack) | ChargeOver current detection current | / |
Detection delay time | / | |
Discharge Over current detection current | 150±30A | |
Detection delay time | 50-350mS | |
Release condition | Cut load,Auto Recovery | |
Short protection | Detection condition | Exterior short circuit |
Detection delay time | 200-600us | |
Release condition | Cut load | |
Resistance | Main loop electrify resistance | ≤20mΩ |
Temperature | high temperature discharge protection | 60℃ |
Operating Temperature Range | -40~+85℃ | |
Storage Temperature Range | -40~+125℃ | |
SIZE: L120*W80*T21mm | ||
NTC: / Temperature switch: 60℃ (the batteries temperature) Weak current switch:/ Activation Method:/ | ||
|