PCM for 1S-2S - AYAA TECHNOLOGY CO., LTD
ホームページ Products
www.ayaatech.com
PCM for 1S-2S PCM-2918-869 (1S) No Test item Criterion Lifepo4 Li-ion/Li-polymer 1 Voltage Charging voltage DC 3.6V CC/CV(3.6V/cell) DC:4.2V CC/CV(4.2V/cell) Balance voltage for single cell …… …… 2 Current Balance current for single cell …… …… Current consumption for single cell ≤20μA ≤20μA Max. continuous charging current 3A 3A Max. cont. discharging current 3A 3A 3 Over charge protection(single cell) Over charge detection voltage 3.90V±0.025V(optional) 4.25±0.025V(optional) Over charge detection delay time 0.5-2.0S 0.5S—2.0S Over charge release voltage 3.805±0.05V 4.05 ±0.05V 4 Over discharge protection(single cell) Over discharge detection voltage 2.00±0.8V(optional) 2.5±0.08V(optional) Over discharge detection delay time 10-300mS 10-300mS Over discharge release voltage 2.3±0.1V 3.0±0.1V 5 Over current protection Over current detection voltage depend on the above points depend on the above points Over current detection current final data fixed from actual test final data fixed from actual test Detection delay time 5-20ms 5-20ms Release condition Cut load,Auto release Cut load,Auto release 6 Short protection Detection condition Exterior short circuit Detection delay time 100~500us Release condition charge up 7 Resistance Protection circuitry ≤50mΩ 8 Temperature Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ 9 Dimension Diameter=17mm Optional Parameters: Over charge detection voltage (V) 4.28±0.025V 4.25±0.025V 3.65±0.025V …
www.ayaatech.com
PCM for 1S-2S PCM-L02S06-879(2S) No Test item Criterion Lifepo4 Li-ion/Li-polymer 1 Voltage Charging voltage DC 7.2V CC/CV(3.6V/cell) DC 8.4V CC/CV(4.2V/cell) Balance voltage for single cell 3.60±0.025V 4.20±0.025V 2 Current Balance current for single cell 36±5mA 42±5mA Current consumption for single cell ≤20μA ≤20μA Max. continuous charging current 5A 5A Max. cont. discharging current 5A 5A 3 Over charge protection(single cell) Over charge detection voltage 3.90V±0.025V(optional) 4.25±0.025V(optional) Over charge detection delay time 0.5-2.0S 0.5S—2.0S Over charge release voltage 3.80±0.05V 4.15 ±0.05V 4 Over discharge protection(single cell) Over discharge detection voltage 2.00±0.8V(optional) 2.5±0.08V(optional) Over discharge detection delay time 10-300mS 10-300mS Over discharge release voltage 2.3±0.1V 3.0±0.1V 5 Over current protection Over current detection voltage depend on the above points depend on the above points Over current detection current final data fixed from actual test final data fixed from actual test Detection delay time 5-20ms 5-20ms Release condition Cut load,Auto release Cut load,Auto release 6 Short protection Detection condition Exterior short circuit Detection delay time 100~500us Release condition charge up 7 Resistance Protection circuitry ≤50mΩ 8 Temperature Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ 9 Dimension L63*W30*T17mm Optional Parameters: Over charge detection voltage (V) 4.28±0.025V 4.25±0.025V 3.65±0.025V Over charge …
www.ayaatech.com
PCM for 1S-2S PCM-L01S05-792(1S) No Test item Criterion Lifepo4 Li-ion/Li-polymer 1 Voltage Charging voltage DC 3.6V CC/CV(3.6V/cell) DC:4.2V CC/CV(4.2V/cell) Balance voltage for single cell …… …… 2 Current Balance current for single cell …… …… Current consumption for single cell ≤20μA ≤20μA Max. continuous charging current 5A 5A Max. cont. discharging current 5A 5A 3 Over charge protection(single cell) Over charge detection voltage 3.90V±0.025V(optional) 4.25±0.025V(optional) Over charge detection delay time 0.5-2.0S 0.5S—2.0S Over charge release voltage 3.805±0.05V 4.05 ±0.05V 4 Over discharge protection(single cell) Over discharge detection voltage 2.00±0.8V(optional) 2.5±0.08V(optional) Over discharge detection delay time 10-300mS 10-300mS Over discharge release voltage 2.3±0.1V 3.0±0.1V 5 Over current protection Over current detection voltage depend on the above points depend on the above points Over current detection current final data fixed from actual test final data fixed from actual test Detection delay time 5-20ms 5-20ms Release condition Cut load,Auto release Cut load,Auto release 6 Short protection Detection condition Exterior short circuit Detection delay time 100~500us Release condition charge up 7 Resistance Protection circuitry ≤50mΩ 8 Temperature Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ 9 Dimension L28*W10*T1.7mm Optional Parameters: Over charge detection voltage (V) 4.28±0.025V 4.25±0.025V 3.65±0.025V Over …
www.ayaatech.com
PCM for 1S-2S PCM-Li02S3-129(2S) No Test item Criterion Lifepo4 Li-ion/Li-polymer 1 Voltage Charging voltage DC 7.2V CC/CV(3.6V/cell) DC:8.4V CC/CV(4.2V/cell) Balance voltage for single cell …… …… 2 Current Balance current for single cell …… …… Current consumption for single cell ≤20μA ≤20μA Max. continuous charging current 5A 5A Max. cont. discharging current 5A 5A 3 Over charge protection(single cell) Over charge detection voltage 3.90V±0.025V(optional) 4.25±0.025V(optional) Over charge detection delay time 0.5-2.0S 0.5S—2.0S Over charge release voltage 3.805±0.05V 4.05 ±0.05V 4 Over discharge protection(single cell) Over discharge detection voltage 2.00±0.8V(optional) 2.5±0.08V(optional) Over discharge detection delay time 10-300mS 10-300mS Over discharge release voltage 2.3±0.1V 3.0±0.1V 5 Over current protection Over current detection voltage depend on the above points depend on the above points Over current detection current final data fixed from actual test final data fixed from actual test Detection delay time 5-20ms 5-20ms Release condition Cut load,Auto release Cut load,Auto release 6 Short protection Detection condition Exterior short circuit Detection delay time 100~500us Release condition charge up 7 Resistance Protection circuitry ≤50mΩ 8 Temperature Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ 9 Dimension L51*W9*T2mm Optional Parameters: Over charge detection voltage (V) 4.28±0.025V 4.25±0.025V 3.65±0.025V Over …
www.ayaatech.com
PCM for 1S-2S Model: PCM-L02S30-A89(LI-2S30A) Test item(Test at normal temperature 25±2℃ ) Criterion Voltage Charging voltage DC:8.4V CC/CV(4.2v/Cell)2s Supply Current Normal operating mode current:Fuel gauge in NORMAL mode. ILOAD >Sleep Current ≤30uA Maximal continuous charging current 30A Maximal continuous discharging current 30A Balance current for single cell 42±10mA Over-charge Protection (single cell) Balance voltage for single cell 4.20±0.05V Over charge detection voltage 4.25±0.05V Over charge detection delay time 0.5S—2S Over charge release voltage 4.05±0.1V Over discharge protection(single cell) Over discharge detection voltage 2.4±0.05V Over discharge detection delay time 10—200mS Over discharge release voltage 3.0±0.1V Current protection(Battery pack) ChargeOver current detection current / Detection delay time / Discharge Over current detection current 100±20A Detection delay time 5ms—60ms Release condition Cut load,Auto Recovery Short protection Detection condition Exterior short circuit Detection delay time 200-600us Release condition Cut load Resistance Main loop electrify resistance ≤60mΩ Temperature Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ SIZE: L120*W35*T6.5 mm NTC: / Temperature switch:/ Weak current switch:/ Activation Method:/
www.ayaatech.com
PCM for 1S-2S PCM-Li02S5-027(2S) No Test item Criterion Lifepo4 Li-ion/Li-polymer 1 Voltage Charging voltage DC 7.2V CC/CV(3.6V/cell) DC:8.4V CC/CV(4.2V/cell) Balance voltage for single cell …… …… 2 Current Balance current for single cell …… …… Current consumption for single cell ≤20μA ≤20μA Max. continuous charging current 5A 5A Max. cont. discharging current 5A 5A 3 Over charge protection(single cell) Over charge detection voltage 3.90V±0.025V(optional) 4.25±0.025V(optional) Over charge detection delay time 0.5-2.0S 0.5S—2.0S Over charge release voltage 3.805±0.05V 4.05 ±0.05V 4 Over discharge protection(single cell) Over discharge detection voltage 2.00±0.8V(optional) 2.5±0.08V(optional) Over discharge detection delay time 10-300mS 10-300mS Over discharge release voltage 2.3±0.1V 3.0±0.1V 5 Over current protection Over current detection voltage depend on the above points depend on the above points Over current detection current final data fixed from actual test final data fixed from actual test Detection delay time 5-20ms 5-20ms Release condition Cut load,Auto release Cut load,Auto release 6 Short protection Detection condition Exterior short circuit Detection delay time 100~500us Release condition charge up 7 Resistance Protection circuitry ≤50mΩ 8 Temperature Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ 9 Dimension L33.5*W16*T3mm Optional Parameters: Over charge detection voltage (V) 4.28±0.025V 4.25±0.025V 3.65±0.025V Over …
www.ayaatech.com
PCM for 1S-2S PCM-Li01S3-216(1S) No Test item Criterion Lifepo4 Li-ion/Li-polymer 1 Voltage Charging voltage DC 3.6V CC/CV(3.6V/cell) DC:4.2V CC/CV(4.2V/cell) Balance voltage for single cell …… …… 2 Current Balance current for single cell …… …… Current consumption for single cell ≤20μA ≤20μA Max. continuous charging current 2.5A 2.5A Max. cont. discharging current 2.5A 2.5A 3 Over charge protection(single cell) Over charge detection voltage 3.90V±0.025V(optional) 4.25±0.025V(optional) Over charge detection delay time 0.5-2.0S 0.5S—2.0S Over charge release voltage 3.805±0.05V 4.05 ±0.05V 4 Over discharge protection(single cell) Over discharge detection voltage 2.00±0.8V(optional) 2.5±0.08V(optional) Over discharge detection delay time 10-300mS 10-300mS Over discharge release voltage 2.3±0.1V 3.0±0.1V 5 Over current protection Over current detection voltage depend on the above points depend on the above points Over current detection current final data fixed from actual test final data fixed from actual test Detection delay time 5-20ms 5-20ms Release condition Cut load,Auto release Cut load,Auto release 6 Short protection Detection condition Exterior short circuit Detection delay time 100~500us Release condition charge up 7 Resistance Protection circuitry ≤50mΩ 8 Temperature Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ 9 Dimension L29.5*W6.5*T2.5mm Optional Parameters: Over charge detection voltage (V) 4.28±0.025V 4.25±0.025V 3.65±0.025V Over …
www.ayaatech.com
PCM for 1S-2S PCM-Li02S3-076(2S) No Test item Criterion Lifepo4 Li-ion/Li-polymer 1 Voltage Charging voltage DC:7.2V CC/CV(3.6V/cell) DC:8.4V CC/CV(4.2V/cell) Balance voltage for single cell …… …… 2 Current Balance current for single cell …… …… Current consumption for single cell ≤20μA ≤20μA Max. continuous charging current 2.5A 2.5A Max. cont. discharging current 2.5A 2.5A 3 Over charge protection(single cell) Over charge detection voltage 3.90V±0.025V(optional) 4.25±0.025V(optional) Over charge detection delay time 0.5-2.0S 0.5S—2.0S Over charge release voltage 3.805±0.05V 4.05 ±0.05V 4 Over discharge protection(single cell) Over discharge detection voltage 2.00±0.8V(optional) 2.5±0.08V(optional) Over discharge detection delay time 10-300mS 10-300mS Over discharge release voltage 2.3±0.1V 3.0±0.1V 5 Over current protection Over current detection voltage depend on the above points depend on the above points Over current detection current final data fixed from actual test final data fixed from actual test Detection delay time 5-20ms 5-20ms Release condition Cut load,Auto release Cut load,Auto release 6 Short protection Detection condition Exterior short circuit Detection delay time 100~500us Release condition charge up 7 Resistance Protection circuitry ≤50mΩ 8 Temperature Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ 9 Dimension L33*W14.7mm Optional Parameters: Over charge detection voltage (V) 4.28±0.025V 4.25±0.025V 3.65±0.025V Over charge …
www.ayaatech.com
PCM for 1S-2S PCM-Li01S8-015(1S) No Test item Criterion Lifepo4 Li-ion/Li-polymer 1 Voltage Charging voltage DC 3.6V CC/CV(3.6V/cell) DC:4.2V CC/CV(4.2V/cell) Balance voltage for single cell …… …… 2 Current Balance current for single cell …… …… Current consumption for single cell ≤20μA ≤20μA Max. continuous charging current 5A 5A Max. cont. discharging current 5A 5A 3 Over charge protection(single cell) Over charge detection voltage 3.90V±0.025V(optional) 4.25±0.025V(optional) Over charge detection delay time 0.5-2.0S 0.5S—2.0S Over charge release voltage 3.805±0.05V 4.05 ±0.05V 4 Over discharge protection(single cell) Over discharge detection voltage 2.00±0.8V(optional) 2.5±0.08V(optional) Over discharge detection delay time 10-300mS 10-300mS Over discharge release voltage 2.3±0.1V 3.0±0.1V 5 Over current protection Over current detection voltage depend on the above points depend on the above points Over current detection current final data fixed from actual test final data fixed from actual test Detection delay time 5-20ms 5-20ms Release condition Cut load,Auto release Cut load,Auto release 6 Short protection Detection condition Exterior short circuit Detection delay time 100~500us Release condition charge up 7 Resistance Protection circuitry ≤50mΩ 8 Temperature Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ 9 Dimension L32*W5*T2.0mm Optional Parameters: Over charge detection voltage (V) 4.28±0.025V 4.25±0.025V 3.65±0.025V Over …
www.ayaatech.com
PCM for 1S-2S PCM-LB2S15A-AY329 (LI-2S15A) Model: PCM-LB2S15A-AY329 (LI-2S15A) Ver: A Test item (Test at normal temperature 25±2℃) Criterion Voltage Charging voltage DC: 8.4V CC/CV(4.2V/Cell)2s Supply Current Normal operating mode current: Fuel gauge in NORMAL mode. ILOAD >Sleep Current ≤30uA Maximal continuous charging current 15A Maximal continuous discharging current 15A Balance current for single cell 42±10mA Over-charge Protection(single cell) Balance voltage for single cell 4.20±0.05V Over charge detection voltage 4.25±0.05V Over charge detection delay time 0.5S—2S Over charge release voltage 4.05±0.1V Over discharge protection(single cell) Over discharge detection voltage 2.8±0.05V Over discharge detection delay time 10—200mS Over discharge release voltage 3.0±0.1V Current protection (Battery pack) Discharge Over current detection current 40±10A Detection delay time 5ms—20ms Release condition Cut load, Auto Recovery Short protection Detection condition Exterior short circuit Detection delay time 200-600us Release condition Cut load Resistance Main loop electrify resistance ≤60mΩ Temperature Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ SIZE: L55*W20*T2.8 mm NTC: / Temperature switch:/ Weak current switch:/ special requirement: /
www.ayaatech.com
PCM for 1S-2S PCM-Li01S3-078(1S) No Test item Criterion Lifepo4 Li-ion/Li-polymer 1 Voltage Charging voltage DC 3.6V CC/CV(3.6V/cell) DC:4.2V CC/CV(4.2V/cell) Balance voltage for single cell …… …… 2 Current Balance current for single cell …… …… Current consumption for single cell ≤20μA ≤20μA Max. continuous charging current 2.5A 2.5A Max. cont. discharging current 2.5A 2.5A 3 Over charge protection(single cell) Over charge detection voltage 3.90V±0.025V(optional) 4.25±0.025V(optional) Over charge detection delay time 0.5-2.0S 0.5S—2.0S Over charge release voltage 3.805±0.05V 4.05 ±0.05V 4 Over discharge protection(single cell) Over discharge detection voltage 2.00±0.8V(optional) 2.5±0.08V(optional) Over discharge detection delay time 10-300mS 10-300mS Over discharge release voltage 2.3±0.1V 3.0±0.1V 5 Over current protection Over current detection voltage depend on the above points depend on the above points Over current detection current final data fixed from actual test final data fixed from actual test Detection delay time 5-20ms 5-20ms Release condition Cut load,Auto release Cut load,Auto release 6 Short protection Detection condition Exterior short circuit Detection delay time 100~500us Release condition charge up 7 Resistance Protection circuitry ≤50mΩ 8 Temperature Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ 9 Dimension L30*W5.5*T2.5mm Optional Parameters: Over charge detection voltage (V) 4.28±0.025V 4.25±0.025V 3.65±0.025V Over …
Battery Series | Model | Picture | Working Current | Balance | Size | Remark |
---|---|---|---|---|---|---|
1S | PCM-2918-869 (1S) | 3A | D17*T2 mm | D17*T2 mm | N/A | |
1S | PCM-L01S05-792(1S) | 5A | NO | L28*W10*T2 mm | N/A | |
1S | PCM-Li01S3-216(1S) | 2.5A | NO | L29.5*W6.5*T2.5mm | N/A | |
1S | PCM-Li01S8-015(1S) | 5A | NO | L32*W5*T2.0mm | N/A | |
1S | PCM-Li01S3-078(1S) | 2.5A | NO | L30*W5.5*T2.5mm | N/A | |
2S | PCM-L02S06-879(2S) | 5A | NO | L34.5*W16mm | with Temperature Switch | |
2S | PCM-Li02S3-129(2S) | 5A | NO | L40*W7*T2.5 mm | N/A | |
2S | PCM-L02S30-A89 | 30A | NO | L120*W35*T6.5 mm | N/A | |
2S | PCM-Li02S5-027(2S) | 5A | NO | L33.5*W16*T3mm | N/A | |
2S | PCM-Li02S3-076(2S) | 2.5A | NO | L33*W14.7*T2 mm | N/A | |
2S | PCM-LB2S15A-AY329 | 15A | NO | L55*W20*T2.8 mm | N/A |