BMS for Medical equipment - AYAA TECHNOLOGY CO., LTD

BMS for Medical equipment - AYAA TECHNOLOGY CO., LTD

BMS for Medical equipment

Dependable Battery Management Systems (BMS) for medical equipment are provided by Shenzhen Ayaa Technology Co., Ltd. The longevity, effectiveness, and safety of batteries used in vital medical devices are guaranteed by our BMS systems. With an emphasis on fault tolerance and high performance, our technology contributes to continuous operation, reduces downtime, and supplies dependable power for life-saving medical applications, improving patient care and device reliability.

  • Research
    15S60A BMS for Medical equipment

    www.ayaatech.com

    15S60A BMS for Medical equipment

    Model Number PCM-L15S60-E92(A-1) Communication Interface SMBUS Charging voltage DC:58.8V CC/CV(4.2v/Cell)14s Maximal continuous charging current 30A Maximal continuous discharging current 30A Current consume in normal operation ≤600uA Balance current for single cell 42±10mA Balance voltage for single cell 4.20±0.10V Over charge detection voltage 4.25±0.05V Over discharge detection voltage 25±3A Charge Over current detection current 1 / ChargeOver current detection current 2 / Discharge Over current detection current 1 32±3A Discharge Over current detection current 2 180±10A Short Protection YES Technical Specification size L160 * W63 * T20 mm NTC 10k Temperature switch /℃(the batteries temperature) Weak currentswitch / Active balance / Heater / Braking Resistors / Other Parameter Low temperature protOperating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ Temperature Parameter LCD display screen / LED light board / Bluetooth mode / 4G / GPS / Optional Configuration

  • Research
    7S30A BMS for Medical equipment

    www.ayaatech.com

    7S30A BMS for Medical equipment

    Model Number PCM-L07S30-C29 Communication Interface SMBUS Charging voltage DC:20.7V~25.2V CC/CV(3.45V~4.2V/Cell)6s Maximal continuous charging current 10-30A Maximal continuous discharging current 10-30A Current consume in normal operation 600 uA Over charge detection voltage 3.6-4.35V Over discharge detection voltage 2.0-3.0V Over current detection current 30-90A Charge Over current detection current 1 / ChargeOver current detection current 2 / Discharge Over current detection current 1 / Discharge Over current detection current 2 / Short Protection YES Technical Specification size L126*W65*T6mm NTC / Temperature switch 66 ℃(the batteries temperature) Weak currentswitch / Active balance / Heater / Braking Resistors / Other Parameter Low temperature protOperating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ Temperature Parameter LCD display screen / LED light board / Bluetooth mode / 4G / GPS / Optional Configuration

  • Research
    4S15A BMS manufacturer for Medical equipment

    www.ayaatech.com

    4S15A BMS manufacturer for Medical equipment

    Model Number PCM-L04S15-E58 Communication Interface SMBUS Charging voltage DC:13.8V~16.8V CC/CV(3.45V~4.2V/Cell)4s Maximal continuous charging current 5-15A Maximal continuous discharging current 5-15A Current consume in normal operation 600 uA Over charge detection voltage 3.6-4.35V Over discharge detection voltage 2.0-3.0V Over current detection current 15-45A Charge Over current detection current 1 / ChargeOver current detection current 2 / Discharge Over current detection current 1 / Discharge Over current detection current 2 / Short Protection YES Technical Specification size L70*W34*T4mm NTC 10K Temperature switch / ℃(the batteries temperature) Weak currentswitch / Active balance / Heater / Braking Resistors / Other Parameter Low temperature protOperating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ Temperature Parameter LCD display screen / LED light board / Bluetooth mode / 4G / GPS / Optional Configuration

  • Research
    OEM/ODM 4S7A BMS for Medical equipment

    www.ayaatech.com

    OEM/ODM 4S7A BMS for Medical equipment

    Model Number PCM-L04S07-E28 Communication Interface SMBUS Charging voltage DC: 14.4V CC/CV(4.2V/1cell) Current consume in normal operation 600 uA Over charge detection voltage 4.25±0.05V Over discharge detection voltage 2.5±0.10V Over current detection current 10±2A Charge Over current detection current 1 / ChargeOver current detection current 2 / Discharge Over current detection current 1 / Discharge Over current detection current 2 / Short Protection YES Technical Specification size L65 *W18 *T4 mm NTC 10K Temperature switch / ℃(the batteries temperature) Weak currentswitch / Active balance / Heater / Braking Resistors / Other Parameter Low temperature protOperating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ Temperature Parameter LCD display screen / LED light board / Bluetooth mode / 4G / GPS / Optional Configuration

  • Research
    4S7A BMS for Medical equipment

    www.ayaatech.com

    4S7A BMS for Medical equipment

    Model Number AY-LB4S7A-T005 Communication Interface SMBUS Charging voltage DC:16.8V CC/CV(4.2v/Cell)4s Maximal continuous charging current 7A Maximal continuous discharging current 7A Current consume in normal operation ≤500uA Over charge detection voltage 2.50±0.1V Over discharge detection voltage 4.25±0.05V Charge Over current detection current 1 8±1A ChargeOver current detection current 2 9±1A Discharge Over current detection current 1 15±2A Discharge Over current detection current 2 22±2A Short Protection YES Technical Specification size L60 * W35 * T7 mm NTC 10K Temperature switch / ℃(the batteries temperature) Weak currentswitch / Active balance / Heater / Braking Resistors / Other Parameter Low temperature protOperating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ Temperature Parameter LCD display screen / LED light board / Bluetooth mode / 4G / GPS / Optional Configuration

  • Research
    13S20A BMS for Medical equipment

    www.ayaatech.com

    13S20A BMS for Medical equipment

    Model Number PCM-L13S20A-A44V4 Communication Interface I2C Charging voltage DC:54.6V CC/CV(4.2v/Cell)13S Maximal continuous charging current 20A Maximal continuous discharging current 20A Current consume in normal operation ≤160uA Over charge detection voltage 2.5±0.05V Over discharge detection voltage 4.25±0.05V charge current protection 15-60A Charge Over current detection current 1 / ChargeOver current detection current 2 / Discharge Over current detection current 1 40±10A Discharge Over current detection current 2 / Short Protection YES Technical Specification size L120 *W65 *T8 mm NTC 10K Temperature switch 65 ℃ (the batteries temperature) Weak currentswitch / Active balance / Heater / Braking Resistors / Other Parameter Low temperature protOperating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ Temperature Parameter LCD display screen / LED light board / Bluetooth mode / 4G / GPS / Optional Configuration

Battery Series Model Picture Working Current Balance Size Remark
    Chat With Us

    Leave Your Message

    • Message