15S 20A BMS of LiFePO4 Battery Replacement for Lead-Acid Battery - AYAA

BMS of LiFePO4 Battery Replacement for Lead-Acid Battery Model:PCM-L15S20-K16 No. Test item (Test at normal temperature 25±2℃ and relative humidity≤90%) Criterion 1 Communication Interface RS485&U ... - AYAA

INQUIRY NOW LINKEDIN FACEBOOK YOUTUBE
  • 15S 20A BMS of LiFePO4 Battery Replacement for Lead-Acid Battery
  • 15S 20A BMS of LiFePO4 Battery Replacement for Lead-Acid Battery
  • 15S 20A BMS of LiFePO4 Battery Replacement for Lead-Acid Battery
  • 15S 20A BMS of LiFePO4 Battery Replacement for Lead-Acid Battery
  • 15S 20A BMS of LiFePO4 Battery Replacement for Lead-Acid Battery
  • 15S 20A BMS of LiFePO4 Battery Replacement for Lead-Acid Battery
  • 15S 20A BMS of LiFePO4 Battery Replacement for Lead-Acid Battery
  • 15S 20A BMS of LiFePO4 Battery Replacement for Lead-Acid Battery
  • 15S 20A BMS of LiFePO4 Battery Replacement for Lead-Acid Battery
  • 15S 20A BMS of LiFePO4 Battery Replacement for Lead-Acid Battery

15S 20A BMS of LiFePO4 Battery Replacement for Lead-Acid Battery

  • Model:PCM-L15S20-K16 
  • Working Current:20A
  • Size:L120*W63*T13mm
  • Battery Type:Li-ion/LiFePO4
  • Battery Series:15S
Inquire Online Download
Parameter information Product Detail

BMS of LiFePO4 Battery Replacement for Lead-Acid Battery

Model:PCM-L15S20-K16
No. Test item
(Test at normal temperature 25±2℃ and relative humidity≤90%)
Criterion
1Communication Interface RS485&UART
&Bluetooth
2VoltageCharging voltageDC:51.75V~63V CC/CV(3.45V~4.2V/Cell)15s
Cell-balance detection voltage(Charge balance) can be adjusted by required
Cell-balance detection delay time 0.5S—2S
3CurrentBalance current for single cell 32-58mA
Normal operating-mode current (Gas Gauge IC)600 uA(average)
SLEEP operating-mode current (Gas Gauge IC)350 uA(average)
Maximal continuous charging current 5-20A
Maximal continuous discharging current 5-20A
4Over charge Protection (single cell)Over charge detection voltage 3.6-4.35V
Over charge detection delay time0.5S—2S
Over charge release voltage3.4-4.15V
5Over discharge protection (single cell)Over discharge detection voltage2.0-3.0V
Over discharge detection delay time150—300mS
Over discharge release voltage2.3-3.2V
6Over current protection(Battery pack) Over current detection current 15-60A
Detection delay time 50ms—300ms
Release condition Cut load,Auto Recovery
7Short protection Detection condition Exterior short circuit
Detection delay time 200-800us
Release condition Cut load,Auto Recovery
8Resistance Protection circuitry (MOSFET)≤50mΩ
9Temperature Operating Temperature Range -40~+85℃
Storage Temperature Range -40~+125℃
Pre-charge/discharge
SIZE: L120 *W63 *T13 mm
NTC: 10K NTC Temperature switch:/ Weak current switch:/ Activation Method:/