PCM-L04S100-L15(Aluminum based substrate)4S 100A BMS of LiFePO4 Battery Replacement for Lead-Acid Battery - AYAA

BMS of LiFePO4 Battery Replacement for Lead-Acid Battery Model: PCM-L04S100-L15(Aluminum based substrate) Test item(Test at normal temperature 25±2℃ ) Criterion Voltage Charging voltage DC:13.8V~16.8V ... - AYAA

INQUIRY NOW LINKEDIN FACEBOOK YOUTUBE
  • PCM-L04S100-L15(Aluminum based substrate)4S 100A BMS of LiFePO4 Battery Replacement for Lead-Acid Battery
  • PCM-L04S100-L15(Aluminum based substrate)4S 100A BMS of LiFePO4 Battery Replacement for Lead-Acid Battery
  • PCM-L04S100-L15(Aluminum based substrate)4S 100A BMS of LiFePO4 Battery Replacement for Lead-Acid Battery
  • PCM-L04S100-L15(Aluminum based substrate)4S 100A BMS of LiFePO4 Battery Replacement for Lead-Acid Battery
  • PCM-L04S100-L15(Aluminum based substrate)4S 100A BMS of LiFePO4 Battery Replacement for Lead-Acid Battery
  • PCM-L04S100-L15(Aluminum based substrate)4S 100A BMS of LiFePO4 Battery Replacement for Lead-Acid Battery
  • PCM-L04S100-L15(Aluminum based substrate)4S 100A BMS of LiFePO4 Battery Replacement for Lead-Acid Battery
  • PCM-L04S100-L15(Aluminum based substrate)4S 100A BMS of LiFePO4 Battery Replacement for Lead-Acid Battery
  • PCM-L04S100-L15(Aluminum based substrate)4S 100A BMS of LiFePO4 Battery Replacement for Lead-Acid Battery
  • PCM-L04S100-L15(Aluminum based substrate)4S 100A BMS of LiFePO4 Battery Replacement for Lead-Acid Battery

PCM-L04S100-L15(Aluminum based substrate)4S 100A BMS of LiFePO4 Battery Replacement for Lead-Acid Battery

  • Model:PCM-L04S100-L15 
  • Working Current:100A
  • Size:L190*W100*T12mm 
  • Battery Type:Li-ion/LiFePO4
  • Battery Series:4S
Inquire Online Download
Parameter information Product Detail

BMS of LiFePO4 Battery Replacement for Lead-Acid Battery

Model: PCM-L04S100-L15(Aluminum based substrate)
Test item(Test at normal temperature 25±2℃ )Criterion
VoltageCharging voltageDC:13.8V~16.8V CC/CV(3.45V~4.2V/Cell)4s
Supply CurrentNormal operating mode current:Fuel gauge in NORMAL mode. ILOAD >Sleep Current≤50uA
Maximal continuous charging current30-100A
Maximal continuous discharging current30-100A
Balance current for single cell36-42mA
Over-charge Protection
(single cell)
Balance voltage for single cell3.6-4.20V
Over charge detection voltage3.6-4.40V
Over charge detection delay time0.5S—2S
Over charge release voltage3.5-4.30V
Over discharge protection
(single cell)
Over discharge detection voltage2.4-3.0V
Over discharge detection delay time10—200mS
Over discharge release voltage2.6-3.4V
Current protection
(Battery pack)
Discharge Over current detection current90-300A
Detection delay time 5ms—20ms
Release conditionCut load,Auto Recovery
Short protectionDetection conditionExterior short circuit
Detection delay time200-600us
Release conditionCut load
ResistanceMain loop electrify resistance ≤65mΩ
TemperatureOperating Temperature Range-40~+85℃
Storage Temperature Range-40~+125℃
SIZE: L190 *W100 *T12 mm
NTC: 10K NTC Temperature switch:90℃ Weak current switch:/ Activation Method:/