PCM-L16S200-H69 (16S 200A) PCM for 10S-16S - BMS-ES APP

PCM for 10S-16S Model:  PCM-L16S200-H69(LI-16S200A)          ver:  A Test   item(Test at normal temperature 25±2℃ ) Criterion Voltage Charging voltage DC:57.6V  CC/CV(3.6V/Cell)16S Supply Current Norm ... - BMS-ES APP

INQUIRY NOW LINKEDIN FACEBOOK YOUTUBE
  • PCM-L16S200-H69 (16S 200A) PCM for 10S-16S
  • PCM-L16S200-H69 (16S 200A) PCM for 10S-16S
  • PCM-L16S200-H69 (16S 200A) PCM for 10S-16S
  • PCM-L16S200-H69 (16S 200A) PCM for 10S-16S
  • PCM-L16S200-H69 (16S 200A) PCM for 10S-16S
  • PCM-L16S200-H69 (16S 200A) PCM for 10S-16S
  • PCM-L16S200-H69 (16S 200A) PCM for 10S-16S
  • PCM-L16S200-H69 (16S 200A) PCM for 10S-16S
  • PCM-L16S200-H69 (16S 200A) PCM for 10S-16S
  • PCM-L16S200-H69 (16S 200A) PCM for 10S-16S

PCM-L16S200-H69 (16S 200A) PCM for 10S-16S

  • Model:PCM-L16S200-H69
  • Working Current:200A
  • Size:L300*W140*T15 mm
  • Battery Type:LiFePO4
  • Battery Series:16S
Inquire Online Download
Parameter information Product Detail

PCM for 10S-16S

Model:  PCM-L16S200-H69(LI-16S200A)          ver:  A
Test   item(Test at normal temperature 25±2℃ ) Criterion
Voltage Charging voltage DC:57.6V  CC/CV(3.6V/Cell)16S
Supply Current Normal operating mode current: Fuel gauge in    NORMAL mode. ILOAD >Sleep Current ≤50uA
Maximal continuous charging current 200A
Maximal continuous discharging current 200A
Balance current for single cell 42±10mA
Over-charge Protection
(single cell)
Balance voltage for single cell 4.20V±0.05V
Over charge detection voltage 4.25±0.05V
Over charge detection delay time 0.5S—2S
Over charge release voltage 4.15±0.1V
Over discharge protection
(single cell)
Over discharge detection voltage 2.75±0.05V
Over discharge detection delay time 1—3S
Over discharge release voltage 3.0±0.1V
Current protection
(Battery pack)
ChargeOver current detection current /
Detection delay time /
Discharge Over current detection current 450±50A
Detection delay time 50-350mS
Release condition Cut load, Auto Recovery
Short protection Detection condition Exterior short circuit
Detection delay time 200-600us
Release condition Cut load
Resistance Main loop electrify resistance ≤20mΩ
Temperature high temperature discharge protection 60℃
Operating Temperature Range -40~+85℃
Storage Temperature Range -40~+125℃
SIZE: L300*W140*T15 mm
NTC: /         Temperature switch: 60℃ (the batteries temperature)          Weak current switch:/          Activation Method:/

B+=P+=Charge+    

CH-=Charge-

P-=Discharge-