CV243 LI-2S BQ27210
Smart Battery Managment with Fuel Guage
Model: | CV243 |
---|---|
Working current: | 5A |
Size: | L50*W14*T2.6 mm |
Balancing: | YES |
Temp. control: | YES |
Battery Type: | Li-ion/Li-po |
Battery Series: | 2S |
Continuous Current: | 5A |
Model: | CV243 |
---|---|
Working current: | 5A |
Size: | L50*W14*T2.6 mm |
Balancing: | YES |
Temp. control: | YES |
Battery Type: | Li-ion/Li-po |
Battery Series: | 2S |
Continuous Current: | 5A |
Protection Circuit Module Specifications For 7.4V Li-ion/Li-Po Battery Pack
|
||||
Model: CV243 LI-2S IC: BQ27210
|
||||
No.
|
Test item (Test at normal temperature 25±2℃ and relative humidity≤90%)
|
Criterion
|
||
1
|
Communication Interface
|
HDQ or I2C
|
||
2
|
Capacity
|
Designing battery capacity
|
/mAh
|
|
Designing battery capacity
|
/mAh
|
|||
Max capacity(Battery pack)
|
/mAh
|
|||
Min capacity(Battery pack)
|
/mAh
|
|||
External capacity Indication
|
|
|||
Gas gauge algorithm
|
Impedance Track
|
|||
3
|
Voltage
|
Charging voltage
|
DC: 8.4V CC/CV(4.2V/1cell)
|
|
Balance voltage for single cell
|
4.20±0.05V
|
|||
4
|
Current
|
Balance current for single cell
|
84±10mA
|
|
Normal operating-mode current:Gas Gauge in NORMAL mode,ILOAD > Sleep Current
|
160 uA
|
|||
SLEEP operating-mode current:Gas Gauge in SLEEP mode,ILOAD < Sleep Current
|
80 uA
|
|||
FULL SLEEP operating-mode current:Gas Gauge in FULL SLEEP mode,ILOAD < Sleep Current
|
25 uA
|
|||
Maximal continuous charging current
|
5A
|
|||
Maximal continuous discharging current
|
5A
|
|||
5
|
Over charge Protection
|
Over charge detection voltage
|
4.25±0.05V
|
|
Over charge detection delay time
|
0.5S—2S
|
|||
Over charge release voltage
|
4.05±0.1V
|
|||
6
|
Over discharge protection
|
Over discharge detection voltage
|
2.8±0.1V
|
|
Over discharge detection delay time
|
10—1000mS
|
|||
Over discharge release voltage
|
3.0±0.1V
|
|||
7
|
Over current protection
|
Over current detection current
|
12±2A
|
|
Detection delay time
|
5ms—60ms
|
|||
Release condition
|
Cut load
|
|||
8
|
Short protection
|
Detection condition
|
Exterior short circuit
|
|
Detection delay time
|
200us-10ms
|
|||
Release condition
|
Cut load
|
|||
9
|
Resistance
|
Protection circuitry
|
≤60mΩ
|
|
|
|
Operating Temperature Range
|
-40~+85℃
|
|
Storage Temperature Range
|
-40~+125℃
|