PCM-L10S10-C19(LI-10S10A)
Smart Battery Managment with Fuel Guage
Model: | PCM-L10S10-C19 |
---|---|
Working Current: | 10A |
Size: | L100*W50*T10mm |
Battery Type: | Li-ion/LiFePO4 |
Battery Series: | 10S |
Model: | PCM-L10S10-C19 |
---|---|
Working Current: | 10A |
Size: | L100*W50*T10mm |
Battery Type: | Li-ion/LiFePO4 |
Battery Series: | 10S |
Model: PCM-L10S10-C19(LI-10S10A) ver: A | ||
Test item(Test at normal temperature 25±2℃ ) | Criterion | |
Communication Interface | I2C ,Bluetooth | |
Voltage | Charging voltage | DC:42V CC/CV(4.2v/Cell)10S |
Capacity | Designing battery capacity(PCM) | 320Ah |
Supply Current | Normal operating mode current:Fuel gauge in NORMAL mode. ILOAD >Sleep Current | ≤400uA |
Maximal continuous charging current | 10A | |
Maximal continuous discharging current | 10A | |
Balance current for single cell | 42±10mA | |
Over-charge Protection (single cell) |
Balance voltage for single cell | 4.2V ±0.05V |
Over charge detection voltage | Optional | |
Over charge detection delay time | 0.5—2S | |
Over charge release voltage | Optional | |
Over discharge protection (single cell) |
Over discharge detection voltage | Optional |
Over discharge detection delay time | 0.5—2S | |
Over discharge release voltage | Optional | |
Current protection (Battery pack) |
Discharge Over current detection current | Adjustable |
Detection delay time | 100—800mS | |
Release condition | Cut load,Auto Recovery | |
Short protection | Detection condition | Exterior short circuit |
Detection delay time | 200-600us | |
Release condition | Cut load | |
Resistance | Main loop electrify resistance | ≤50mΩ |
Temperature | Operating Temperature Range | -40~+85℃ |
Storage Temperature Range | -40~+125℃ | |
SIZE:L100*W50*T10mm | ||
NTC:10KNTC B=3435 Temperature switch:/℃ Weak current switch:/ Activation Method:/ |
Copyright © 2017 AYAA TECHNOLOGY CO.,LTD. All Rights Reserved. Design By Gemelsoft.