• AY-LB10S19A-T006 (10S 20A)
  •  BMS/PCM with Communications - AY-LB10S19A-T006 (10S 20A)

AY-LB10S19A-T006 (10S 20A)

BMS/PCM with Communications

Model: AY-LB10S19A-T006
Working Current: 20A
Size: L90*W35*T7.5 mm
Battery Type: Li-ion/Li-Po/LiFePO4
Battery Series: 10S

  • Description
  • Get quote
Sender email add: RE: AY-LB10S19A-T006 (10S 20A)
  • BMS/PCM with Communications

     

    Model:  AY-LB10S19A-T006   (LB-10S20A)               Ver:  A
    Test   item(Test at normal temperature 25±2℃ ) Criterion
    Communication Interface SMBUS
    Voltage Charging voltage DC: 42V  CC/CV(4.2V/Cell)10s
    Capacity Designing battery capacity(PCM) /Ah
    Supply Current Normal operating mode current:Fuel gauge in      NORMAL mode. ILOAD >Sleep Current ≤860uA
    Low-power operating mode current:Fuel gauge in SLEEP mode. ILOAD < Sleep Current ≤430 uA
    Low-power operating mode current:Fuel gauge in FULLSLEEP mode.ILOAD < Sleep Current ≤12uA
    Maximal continuous charging current 20A
    Maximal continuous discharging current 20A
    Balance current for single cell 42±10mA
    Over-charge Protection
    (single cell)
    Balance voltage for single cell 4.2V±0.05V
    Over charge detection voltage 4.30±0.05V
    Over charge detection delay time 0.5S—2S
    Over charge release voltage 4.10±0.1V
    Over discharge protection
    (single cell)
    Over discharge detection voltage 2.8±0.05V
    Over discharge detection delay time 0.5S—2S
    Over discharge release voltage 3.0±0.1V
    Current protection
    (Battery pack)
    ChargeOver current detection current 20±3A
    Detection delay time   0.5S—2S
    Discharge Over current detection current 850±10A
    Detection delay time   0.5S—2S
    Release condition Cut load, Auto Recovery
    Short protection Detection condition Exterior short circuit
    Detection delay time 200-600us
    Release condition Cut load
    Resistance Main loop electrify resistance  ≤ 30mΩ
    Temperature discharge  temperature  protection  -10~+65℃
    charge temperature   protection 0~+60℃
    Operating Temperature Range -40~+85℃
    Storage Temperature Range -40~+125℃
    SIZE: L90*W35*T7.5 mm
    NTC: 10KNTC B=3435  75℃ cut off  Temperature switch: / ℃ (the batteries temperature)   Weak current switch:/   Activation Method:/

                                   

Copyright © 2017 AYAA TECHNOLOGY CO.,LTD. All Rights Reserved. Design By Gemelsoft.