AY-LX6S15A-T016 BQ34Z100
BMS/PCM with Communications
Model: | AY-LX6S15A-T016 |
---|---|
Working Current: | 15A |
Size: | L52*W34*T6 mm |
Battery Type: | Li-ion/Li-Po/LiFePO4 |
Battery Series: | 6S |
Model: | AY-LX6S15A-T016 |
---|---|
Working Current: | 15A |
Size: | L52*W34*T6 mm |
Battery Type: | Li-ion/Li-Po/LiFePO4 |
Battery Series: | 6S |
Model: AY-LX6S15A-T016 Ver: A BQ34Z100 | ||
Test item (Test at normal temperature 25±2℃) | Criterion | |
Communication Interface | I2C | |
Voltage | Charging voltage | DC: 25.2V CC/CV(4.2V/Cell)6s |
Capacity | Designing battery capacity (PCM) | /Ah |
Supply Current | Normal operating mode current: Fuel gauge in NORMAL mode. ILOAD >Sleep Current | ≤200uA |
Low-power operating mode current: Fuel gauge in SLEEP mode. ILOAD < Sleep Current | ≤130 uA | |
Low-power operating mode current: Fuel gauge in FULLSLEEP mode. ILOAD < Sleep Current | ≤12uA | |
Maximal continuous charging current | 12A | |
Maximal continuous discharging current | 12A | |
Balance current for single cell | / | |
Over-charge Protection (single cell) |
Balance voltage for single cell | / |
Over charge detection voltage | 4.25±0.025V | |
Over charge detection delay time | 1S | |
Over charge release voltage | 4.15±0.1V | |
Over discharge protection (single cell) |
Over discharge detection voltage | 2.7±0.05V |
Over discharge detection delay time | 1S | |
Over discharge release voltage | 3.0±0.1V | |
Current protection (Battery pack) |
Discharge Over current detection current1 | 40±10A |
Detection delay time | 1S | |
Discharge Over current detection current2 | 80±10A | |
Detection delay time | 100ms | |
Release condition | Cut load, Auto Recovery | |
Short protection | Detection condition | Exterior short circuit |
Detection delay time | 180-300us | |
Release condition | Cut load | |
Temperature | Discharge temperature protection | -10~+65℃ |
Charge temperature protection | 0~+60℃ | |
Operating Temperature Range | -40~+85℃ | |
Storage Temperature Range | -40~+125℃ | |
SIZE: 52*34*6mm | ||
NTC: 10KNTC B=3435 Temperature switch: / ℃ (the batteries temperature) Weak current switch:/ Activation Method:/ |
Copyright © 2017 AYAA TECHNOLOGY CO.,LTD. All Rights Reserved. Design By Gemelsoft.