Protection Circuit Module Specifications For 37V Li-ion/Li-Po Battery Pack |
Model: PCM-L10S10-C19 (LI-10S) |
No. |
Test item(Test at normal temperature 25±2℃ and relative humidity≤90%) |
Criterion |
1 |
Communication Interface |
HDQ or I2C |
2 |
Capacity |
Designing battery capacity |
8500mAh |
Designing battery capacity |
8500mAh |
Max capacity(Battery pack) |
320000mAh |
Min capacity(Battery pack) |
800mAh |
External capacity Indication |
|
Gas gauge algorithm |
Impedance Track |
3 |
Voltage |
Charging voltage |
DC: 37V CC/CV(4.2V/1cell) |
Balance voltage for single cell |
4.2±0.05V |
4 |
Current |
Balance current for single cell |
68±10mA |
Normal operating-mode current:Gas Gauge in NORMAL mode, ILOAD > Sleep Current |
160 uA |
SLEEP operating-mode current:Gas Gauge in SLEEP mode, ILOAD < Sleep Current |
80 uA |
FULL SLEEP operating-mode current:Gas Gauge in FULL SLEEP mode, ILOAD < Sleep Current |
25 uA |
Maximal continuous charging current |
10A |
Maximal continuous discharging current |
10A |
5 |
Over charge Protection |
Over charge detection voltage |
4.25±0.05V |
Over charge detection delay time |
0.5S—2S |
Over charge release voltage |
4.05±0.1V |
6 |
Over discharge protection |
Over discharge detection voltage |
2.75±0.1V |
Over discharge detection delay time |
10—30mS |
Over discharge release voltage |
3.0±0.1V |
7 |
Over current protection |
Over current detection current |
40±5A |
Detection delay time |
5ms—60ms |
Release condition |
Cut load |
8 |
Short protection |
Detection condition |
Exterior short circuit |
Detection delay time |
200-800us |
Release condition |
Cut load |
9 |
Resistance |
Protection circuitry |
≤50mΩ |
10 |
Temperature |
Operating Temperature Range |
-40~+85℃ |
Storage Temperature Range |
-40~+125℃ |