PCM-L05S18-C92
BMS/PCM with Communications
Model: | PCM-L05S18-C92 |
---|---|
Working Current: | 18A |
Size: | L83*W64.5*T6mm |
Battery Type: | Li-ion/LiFePO4 |
Battery Series: | 5S |
Model: | PCM-L05S18-C92 |
---|---|
Working Current: | 18A |
Size: | L83*W64.5*T6mm |
Battery Type: | Li-ion/LiFePO4 |
Battery Series: | 5S |
Model:PCM-L05S18-C92 | ||||
No. |
Test item (Test at normal temperature 25±2℃ and relative humidity≤90%) |
Criterion | ||
1 | Communication Interface | I2C | ||
2 | Voltage | Charging voltage | DC:17.25V~21V CC/CV(3.45V~4.2V/Cell)5s | |
Cell-balance detection voltage(Charge balance) | can be adjusted by required | |||
Cell-balance detection delay time | 0.5S—2S | |||
3 | Current | Normal operating-mode current (Gas Gauge IC) | 600 uA(average) | |
SLEEP operating-mode current (Gas Gauge IC) | 350 uA(average) | |||
Maximal continuous charging current | 5-18A | |||
Maximal continuous discharging current | 5-18A | |||
4 | Over charge Protection (single cell) | Over charge detection voltage | 3.6-4.35V | |
Over charge detection delay time | 0.5S—2S | |||
Over charge release voltage | 3.4-4.15V | |||
5 | Over discharge protection (single cell) | Over discharge detection voltage | 2.0-3.0V | |
Over discharge detection delay time | 150—300mS | |||
Over discharge release voltage | 2.3-3.2V | |||
6 | Over current protection(Battery pack) | Over current detection current | 15-54A | |
Detection delay time | 50ms—300ms | |||
Release condition | Cut load,Auto Recovery | |||
7 | Short protection | Detection condition | Exterior short circuit | |
Detection delay time | 200-800us | |||
Release condition | Cut load,Auto Recovery | |||
8 | Resistance | Protection circuitry (MOSFET) | ≤50mΩ | |
9 | Temperature | Operating Temperature Range | -40~+85℃ | |
Storage Temperature Range | -40~+125℃ | |||
SIZE: L83*W64.5*T6mm | ||||
NTC: 10K NTC Temperature switch:65℃ Weak current switch:/ Activation Method:/ |