PCM-L04S50-J13
BMS/PCM with Communications
Model: | PCM-L04S50-J13 |
---|---|
Working Current: | 50A |
Size: | L120*W68*T8mm |
Battery Type: | Li-ion/LiFePO4 |
Battery Series: | 4S |
Model: | PCM-L04S50-J13 |
---|---|
Working Current: | 50A |
Size: | L120*W68*T8mm |
Battery Type: | Li-ion/LiFePO4 |
Battery Series: | 4S |
Model:PCM-L04S50-J13 | ||||
No. |
Test item (Test at normal temperature 25±2℃ and relative humidity≤90%) |
Criterion | ||
1 | Communication Interface | SMBUS | ||
2 | Voltage | Charging voltage | DC:13.8V~16.8V CC/CV(3.45V~4.2V/Cell)4s | |
Cell-balance detection voltage(Charge balance) | can be adjusted by required | |||
Cell-balance detection delay time | 0.5S—2S | |||
3 | Current | Normal operating-mode current (Gas Gauge IC) | 600 uA(average) | |
SLEEP operating-mode current (Gas Gauge IC) | 350 uA(average) | |||
Maximal continuous charging current | 10-40A | |||
Maximal continuous discharging current | 10-40A | |||
4 | Over charge Protection (single cell) | Over charge detection voltage | 3.6-4.35V | |
Over charge detection delay time | 0.5S—2S | |||
Over charge release voltage | 3.4-4.15V | |||
5 | Over discharge protection (single cell) | Over discharge detection voltage | 2.0-3.0V | |
Over discharge detection delay time | 150—300mS | |||
Over discharge release voltage | 2.3-3.2V | |||
6 | Over current protection(Battery pack) | Over current detection current | 30-120A | |
Detection delay time | 50ms—300ms | |||
Release condition | Cut load,Auto Recovery | |||
7 | Short protection | Detection condition | Exterior short circuit | |
Detection delay time | 200-800us | |||
Release condition | Cut load,Auto Recovery | |||
8 | Resistance | Protection circuitry (MOSFET) | ≤50mΩ | |
9 | Temperature | Operating Temperature Range | -40~+85℃ | |
Storage Temperature Range | -40~+125℃ | |||
SIZE: L120 *W68*T8 mm | ||||
NTC: 10K NTC*2pcs Temperature switch:/ Weak current switch:/ Activation Method:/ |
Copyright © 2017 AYAA TECHNOLOGY CO.,LTD. All Rights Reserved. Design By Gemelsoft.