PCM-L13S50-911(13S 40A)
PCM for 10S-16S
Model: | PCM-L13S50-911 |
---|---|
Working Current: | 40A |
Size: | L100*W60*T20 mm |
Battery Type: | Li-ion/Li-Po |
Battery Series: | 13S |
Model: | PCM-L13S50-911 |
---|---|
Working Current: | 40A |
Size: | L100*W60*T20 mm |
Battery Type: | Li-ion/Li-Po |
Battery Series: | 13S |
Protection Circuit Module Specifications For 48.1V Li-ion/Li-Po Battery Pack | ||||
Model:PCM-L13S50-911(LI-13S) | ||||
No. | Test item | Criterion | ||
1 | Voltage | Charging voltage | DC: 54.6V CC/CV (4.2V/1cell) | |
Balance voltage for single cell | 4.2V±0.025V | |||
2 | Current | Balance current for single cell | 85mA±5mA | |
Current consumption for single cell | ≤20μA | |||
Maximal continuous charging current | 40A | |||
Maximal continuous discharging current | 40A | |||
3 |
Over charge Protection (single cell) |
Over charge detection voltage | 4.25±0.025V | |
Over charge detection delay time | 0.5S—2S | |||
Over charge release voltage | 4.05±0.05V | |||
4 |
Over discharge protection (single cell) |
Over discharge detection voltage | 2.5±0.07V | |
Over discharge detection delay time | 10—30mS | |||
Over discharge release voltage | 3.0±0.1V | |||
5 | Over current protection | Over current detection voltage | 0.2±0.015V | |
Over current detection current | 100±20A | |||
Detection delay time | 5ms—20ms | |||
Release condition | Cut load | |||
6 | Short protection | Detection condition | Exterior short circuit | |
Detection delay time | 200-800us | |||
Release condition | Cut load | |||
7 | Resistance | Protection circuitry (B- TO P-) | ≤30mΩ | |
8 | Temperature | Operating Temperature Range | -40~+85℃ | |
Storage Temperature Range | -40~+125℃ | |||
Over Temperature protection (discharge) | 60±5℃ |