PCM-L10S25-B66(10S 15A)
PCM for 10S-16S
Model: | PCM-L10S25-B66 |
---|---|
Working Current: | 15A |
Size: | L70*W36*T19 mm |
Battery Type: | Li-ion/Li-Po/LiFePO4 |
Battery Series: | 10S |
Model: | PCM-L10S25-B66 |
---|---|
Working Current: | 15A |
Size: | L70*W36*T19 mm |
Battery Type: | Li-ion/Li-Po/LiFePO4 |
Battery Series: | 10S |
Model: PCM-L10S25-B66(A)(LI-10S 15A)ver: A | ||
Test item(Test at normal temperature 25±2℃ ) | Criterion | |
Voltage | Charging voltage | DC:42V CC/CV(4.2v/Cell)10s |
Capacity | Designing battery capacity(PCM) | / |
Supply Current | Normal operating mode current:Fuel gauge in NORMAL mode. ILOAD >Sleep Current | ≤150uA |
Maximal continuous charging current | 5A | |
Maximal continuous discharging current | 25A | |
Balance current for single cell | 68±10mA | |
Over-charge Protection (single cell) |
Balance voltage for single cell | 4.2V±0.05V |
Over charge detection voltage | 4.25±0.05V | |
Over charge detection delay time | 0.5S—2S | |
Over charge release voltage | 4.15±0.1V | |
Over discharge protection (single cell) |
Over discharge detection voltage | 2.75±0.1V |
Over discharge detection delay time | 150—300mS | |
Over discharge release voltage | 3.0±0.1V | |
Current protection (Battery pack) |
ChargeOver current detection current | / |
Detection delay time | / | |
Discharge Over current detection current | 100±20A | |
Detection delay time | 100ms—300ms | |
Release condition | Cut load,Auto Recovery | |
Short protection | Detection condition | Exterior short circuit |
Detection delay time | 200-800us | |
Release condition | Cut load | |
Resistance | Main loop electrify resistance | ≤30mΩ |
Temperature | Operating Temperature Range | -40~+70℃ |
Storage Temperature Range | -40~+125℃ | |
SIZE: L70*W36*T19 mm | ||
NTC: / Temperature switch:65℃ Weak current switch:/ Activation Method:/ | ||