PCM-LB20S400A-AY306(20S220A)
PCM for 17S-35S
Model: | PCM-LB20S400A-AY306 (20S) |
---|---|
Working Current: | 220A |
Size: | L175*W116.5*T18 mm |
Battery Type: | Li-ion/Li-Po |
Battery Series: | 20S |
Model: | PCM-LB20S400A-AY306 (20S) |
---|---|
Working Current: | 220A |
Size: | L175*W116.5*T18 mm |
Battery Type: | Li-ion/Li-Po |
Battery Series: | 20S |
Model: PCM-LB20S400A-AY306(LF-20S220A) ver: A | ||
Test item (Test at normal temperature 25±2℃) | Criterion | |
Voltage | Charging voltage | DC:72V CC/CV(3.6v/Cell)20s |
Supply Current | Normal operating mode current: Fuel gauge in NORMAL mode. ILOAD >Sleep Current | ≤50uA |
Maximal continuous charging current | 220A | |
Maximal continuous discharging current | 220A | |
Balance current for single cell | 36±5mA | |
Over-charge Protection (single cell) |
Balance voltage for single cell | 3.6±0.05V |
Over charge detection voltage | 3.85±0.05V | |
Over charge detection delay time | 0.5S—2S | |
Over charge release voltage | 3.65±0.1V | |
Over discharge protection (single cell) |
Over discharge detection voltage | 2.3±0.05V |
Over discharge detection delay time | 10—200mS | |
Over discharge release voltage | 2.5±0.1V | |
Current protection (Battery pack) |
ChargeOver current detection current | / |
Detection delay time | / | |
Discharge Over current detection current | 800±100A | |
Detection delay time | 5ms—50ms | |
Release condition | Cut load, Auto Recovery | |
Short protection | Detection condition | Exterior short circuit |
Detection delay time | 200-600us | |
Release condition | Cut load | |
Resistance | Main loop electrify resistance | ≤20mΩ |
Temperature | high temperature charge protection | / |
high temperature discharge protection | / | |
Operating Temperature Range | -40~+85℃ | |
Storage Temperature Range | -40~+125℃ | |
SIZE: L175*W116.5*T18 mm | ||
NTC: / Temperature switch:/ (the batteries temperature) Weak current switch:/ Activation Method:/ |
Copyright © 2017 AYAA TECHNOLOGY CO.,LTD. All Rights Reserved. Design By Gemelsoft.