PCM-LB21S40A-AY327(LI-21S40A)
PCM for 17S-35S
Model: | PCM-LB21S40A-AY327 |
---|---|
Working Current: | 40A |
Size: | L80*W60*T16 mm |
Battery Type: | Li-ion/Li-Po |
Battery Series: | 21S |
Model: | PCM-LB21S40A-AY327 |
---|---|
Working Current: | 40A |
Size: | L80*W60*T16 mm |
Battery Type: | Li-ion/Li-Po |
Battery Series: | 21S |
Model: PCM-LB21S40A-AY327(LI-21S40A) ver: A | ||
Test item (Test at normal temperature 25±2℃) | Criterion | |
Voltage | Charging voltage | DC: 88.2V CC/CV(4.2v/Cell)21s |
Capacity | Designing battery capacity(PCM) | /mAh |
Supply Current | Normal operating mode current: Fuel gauge in NORMAL mode. ILOAD >Sleep Current | ≤50uA |
Maximal continuous charging current | 40A | |
Maximal continuous discharging current | 40A | |
Balance current for single cell | 42±10mA | |
Over-charge Protection (single cell) |
Balance voltage for single cell | 4.2V±0.05V |
Over charge detection voltage | 4.25±0.05V | |
Over charge detection delay time | 0.5S—2S | |
Over charge release voltage | 4.15±0.1V | |
Over discharge protection (single cell) |
Over discharge detection voltage | 2.8±0.05V |
Over discharge detection delay time | 0.5S—2S | |
Over discharge release voltage | 3.00±0.1V | |
Current protection (Battery pack) |
Detection delay time | 0.5~2.0S |
Discharge Over current detection current | 120±30A | |
Detection delay time | 5ms—150ms | |
Release condition | Cut load, Auto Recovery | |
Short protection | Detection condition | Exterior short circuit |
Detection delay time | 450~800uS | |
Release condition | Cut load | |
Resistance | Main loop electrify resistance | ≤20mΩ |
Temperature | Operating Temperature Range | -40~+70℃ |
Storage Temperature Range | 0~60℃ | |
Charging high temperature protection | 50±5℃ | |
Discharge high temperature protection | 70±5℃ | |
SIZE: L80*W60*T16 mm | ||
NTC: 10K NTC cut off Temperature switch: / (the batteries temperature) Weak current switch:/ Activation Method:/ |
Copyright © 2017 AYAA TECHNOLOGY CO.,LTD. All Rights Reserved. Design By Gemelsoft.