PCM-LB24S150A-AY072(24S150A)
PCM for 17S-35S
Model: | PCM-LB24S150A-AY072 |
---|---|
Working Current: | 150A |
Size: | L125*W63*T15 mm |
Battery Type: | Li-ion/Li-Po |
Battery Series: | 24S |
Model: | PCM-LB24S150A-AY072 |
---|---|
Working Current: | 150A |
Size: | L125*W63*T15 mm |
Battery Type: | Li-ion/Li-Po |
Battery Series: | 24S |
Model: PCM-LB24S150A-AY072 ver: A | ||
Test item (Test at normal temperature 25±2℃) | Criterion | |
Voltage | Charging voltage | DC: 100.8V CC/CV(4.2v/Cell)24s |
Capacity | Designing battery capacity(PCM) | *mAh |
Supply Current | Normal operating mode current: Fuel gauge in NORMAL mode. ILOAD >Sleep Current | ≤50uA |
Maximal continuous charging current | 150A | |
Maximal continuous discharging current | 150A | |
Balance current for single cell | 42±10mA | |
Over-charge Protection (single cell) |
Balance voltage for single cell | 4.2V±0.05V |
Over charge detection voltage | 4.25±0.05V | |
Over charge detection delay time | 0.5S—2S | |
Over charge release voltage | 4.15±0.1V | |
Over discharge protection (single cell) |
Over discharge detection voltage | 2.75±0.05V |
Over discharge detection delay time | 10—200mS | |
Over discharge release voltage | 3.0±0.1V | |
Current protection (Battery pack) |
ChargeOver current detection current | / |
Detection delay time | / | |
Discharge Over current detection current | 450±50A | |
Detection delay time | 5ms—50ms | |
Release condition | Cut load, Auto Recovery | |
Short protection | Detection condition | Exterior short circuit |
Detection delay time | 200-600us | |
Release condition | Cut load | |
Resistance | Main loop electrify resistance | ≤ 60mΩ |
Temperature | high temperature discharge protection | 65℃ |
Operating Temperature Range | -20~+70℃ | |
Storage Temperature Range | -40~+125℃ | |
SIZE: L125*W63*T15 mm | ||
NTC: / Temperature switch: 65 ℃ (the batteries temperature) Weak current switch:/ Activation Method:/ |
Copyright © 2017 AYAA TECHNOLOGY CO.,LTD. All Rights Reserved. Design By Gemelsoft.