PCM-LB30S80A-AY161(LI-30S60A)
PCM for 17S-35S
Model: | PCM-LB30S80A-AY161 |
---|---|
Working Current: | 80A |
Size: | L110*W65*T20 mm |
Battery Type: | Li-ion/Li-Po |
Battery Series: | 30S |
Model: | PCM-LB30S80A-AY161 |
---|---|
Working Current: | 80A |
Size: | L110*W65*T20 mm |
Battery Type: | Li-ion/Li-Po |
Battery Series: | 30S |
Model: PCM-LB30S80A-AY161(LI-30S80A) ver: A | ||
Test item (Test at normal temperature 25±2℃) | Criterion | |
Voltage | Charging voltage | DC: 126V CC/CV(4.2v/Cell)30s |
Supply Current | Normal operating mode current: Fuel gauge in NORMAL mode. ILOAD >Sleep Current | ≤50uA |
Maximal continuous charging current | 20A | |
Maximal continuous discharging current | 60A | |
Balance current for single cell | 42±10mA | |
Over-charge Protection (single cell) |
Balance voltage for single cell | 4.2V±0.05V |
Over charge detection voltage | 4.25±0.10V | |
Over charge detection delay time | 0.5S—2S | |
Over charge release voltage | 4.10±0.05V | |
Over discharge protection (single cell) |
Over discharge detection voltage | 2.50V±0.10V |
Over discharge detection delay time | 10—200mS | |
Over discharge release voltage | 3000±0.10V | |
Current protection (Battery pack) |
ChargeOver current detection current | / |
Detection delay time | / | |
Discharge Over current detection current | 300±50A | |
Detection delay time | 20ms—500ms | |
Release condition | Cut load, Auto Recovery | |
Short protection | Detection condition | Exterior short circuit |
Detection delay time | 200-600us | |
Release condition | Cut load | |
Resistance | Main loop electrify resistance | ≤20mΩ |
Temperature | Operating Temperature Range | -40~+85℃ |
Storage Temperature Range | -40~+125℃ | |
SIZE: L110*W65*T20 mm | ||
NTC: / Temperature switch: / (the batteries temperature) Weak current switch:/ Activation Method:/ |
Copyright © 2017 AYAA TECHNOLOGY CO.,LTD. All Rights Reserved. Design By Gemelsoft.