AY-LB4S12A-T005-4S10A PCM/BMS
BMS/PCM with Fuel Gauge
Model: | AY-LB4S12A-T005 |
---|---|
Working Current: | 12A |
Size: | L60*W35*T7 mm |
Battery Type: | Li-ion/Li-Po/LiFePO4 |
Battery Series: | 4S |
Model: | AY-LB4S12A-T005 |
---|---|
Working Current: | 12A |
Size: | L60*W35*T7 mm |
Battery Type: | Li-ion/Li-Po/LiFePO4 |
Battery Series: | 4S |
Model: AY-LB4S12A-T005-LB4S10A Ver: A | ||
Test Item (Test at normal temperature 25±2℃) | Criterion | |
Communication Interface | SMBUS BQ40Z50 | |
Voltage | Charging voltage | DC:16.8V CC/CV(4.2V/Cell)4s |
Capacity | Designing battery capacity (PCM) | 32Ah |
Supply Current | Normal operating mode current: Fuel gauge in NORMAL mode. ILOAD >Sleep Current | ≤160uA |
Low-power operating mode current: Fuel gauge in FULLSLEEP mode.ILOAD < Sleep Current | ≤80uA | |
Maximal continuous charging current | 12A | |
Maximal continuous discharging current | 12A | |
Balance current for single cell | 42±10mA | |
Over-charge Protection (single cell) |
Balance voltage for single cell | 4.2V±0.05V |
Over charge detection voltage | 4.25±0.05V | |
Over charge detection delay time | 0.5S—2S | |
Over charge release voltage | 4.10±0.1V | |
Over discharge protection (single cell) |
Over discharge detection voltage | 2.5±0.05V |
Over discharge detection delay time | 0.5S—2S | |
Over discharge release voltage | 3.0±0.1V | |
Current protection (Battery pack) |
ChargeOver current detection current | / |
Detection delay time | / | |
Discharge Over current detection current | 30±5A | |
Detection delay time | 0.5S—2S | |
Release condition | Cut load, Auto Recovery | |
Short protection | Detection condition | Exterior short circuit |
Detection delay time | 200-600us | |
Release condition | Cut load | |
Resistance | Main loop electrify resistance | ≤ 20mΩ |
Temperature | discharge temperature protection | +65℃ |
charge temperature protection | / | |
Operating Temperature Range | -40~+85℃ | |
Storage Temperature Range | -40~+125℃ | |
SIZE: L60*W35*T7mm | ||
NTC: 10KNTC B=3435 Temperature switch:/℃ (the batteries temperature) Weak current switch:/ Activation Method:/ |
Copyright © 2017 AYAA TECHNOLOGY CO.,LTD. All Rights Reserved. Design By Gemelsoft.