PCM-LX3S6A-AY326 Smart BMS PCM for Li-Ion/Li-Po/LiFePO4 Battery with NTC
PCM for 3S-4S
Model: | PCM-LX3S6A-AY326 |
---|---|
Working Current: | 6A |
Size: | L51.3*W14.8*T3.5 mm |
Battery Type: | Li-ion/Li-Po |
Battery Series: | 3S |
Model: | PCM-LX3S6A-AY326 |
---|---|
Working Current: | 6A |
Size: | L51.3*W14.8*T3.5 mm |
Battery Type: | Li-ion/Li-Po |
Battery Series: | 3S |
Model: PCM-LX3S6A-AY326 ver: A | ||
Test item(Test at normal temperature 25±2℃) | Criterion | |
Voltage | Charging voltage | DC:12.6V CC/CV(4.2v/Cell)3s |
Supply Current | Normal operating mode current: Fuel gauge in NORMAL mode. ILOAD >Sleep Current | ≤30uA |
Maximal continuous charging current | 6A | |
Maximal continuous discharging current | 6A | |
Balance current for single cell | / | |
Over-charge Protection (single cell) |
Balance voltage for single cell | / |
Over charge detection voltage | 4.25±0.05V | |
Over charge detection delay time | 0.5S—2S | |
Over charge release voltage | 4.15±0.1V | |
Over discharge protection (single cell) |
Over discharge detection voltage | 2.7±0.05V |
Over discharge detection delay time | 0.5—1.5S | |
Over discharge release voltage | 3.0±0.1V | |
Current protection (Battery pack) |
ChargeOver current detection current | / |
Detection delay time | / | |
Discharge Over current detection current | 20±5A | |
Detection delay time | 0.5s—1.5s | |
Release condition | Cut load, Auto Recovery | |
Short protection | Detection condition | Exterior short circuit |
Detection delay time | 200-500us | |
Release condition | Cut load | |
Resistance | Main loop electrify resistance | ≤50mΩ |
Temperature | high temperature discharge protection | /±5℃ |
Operating Temperature Range | -20~+85℃ | |
Storage Temperature Range | -40~+125℃ | |
SIZE: L51.3*W14.8*T3.5 mm | ||
NTC: 65 ℃ cut off Temperature switch: Weak current switch:/ 特殊激活方式:/ |
Copyright © 2017 AYAA TECHNOLOGY CO.,LTD. All Rights Reserved. Design By Gemelsoft.